RX Heat RX15 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Ohřívače prostoru RX Heat RX15. RX Heat RX15 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 124
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1645 Wallace Drive, Suite 110
Carrollton, TX75006
www.daikinac.com
AMERICAS
EDUS 04 - 904
H-Series
- Heat Pump -
SEER 13 Models
EDUS 04-904 ENGINEERING DATA SPLIT H-Series - Heat Pump -
Specifications, designs and other content appearing in this brochure are current as of November 2008 but subject to change without notice.
EDUS04-904
Printed in U.S.A. 11/2008 B AK
Zobrazit stránku 0
1 2 3 4 5 6 ... 123 124

Shrnutí obsahu

Strany 1 - SEER 13 Models

1645 Wallace Drive, Suite 110Carrollton, [email protected] 04 - 904H-Series- Heat Pump -SEER 13 ModelsEDUS 04-904 E

Strany 2 - Room Air Conditioners

EDUS04-904 DimensionsRoom Air Conditioners H-Series 9FTXS24HVJUAIR FLOW (INDOOR)(FOR PERFORMANCE AND MAINTENANCE)THE MARK (→) SHOWS PIPING DIRECTIONRE

Strany 3 - EDUS04-904

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 99

Strany 4 - 1. Power Supply

Operation Manual EDUS04-904100 Room Air Conditioners H-Series

Strany 5 - 2. Functions

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 101

Strany 6 - 3. Specifications

Operation Manual EDUS04-904102 Room Air Conditioners H-Series

Strany 7 - 60Hz 230V

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 103

Strany 8

Operation Manual EDUS04-904104 Room Air Conditioners H-Series

Strany 9 - 4. Dimensions

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 105

Strany 10 - FTXS24HVJU

Operation Manual EDUS04-904106 Room Air Conditioners H-Series

Strany 11 - 4.2 Outdoor Units

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 107

Strany 12 - RX24FVJU

Operation Manual EDUS04-904108 Room Air Conditioners H-Seriesodor.

Strany 13 - 5. Wiring Diagrams

Dimensions EDUS04-90410 Room Air Conditioners H-Series4.2 Outdoor UnitsRX09/12FAVJURX15/18FVJUNAMEPLATEDRAIN OUTLETTERMINAL STRIPWITH GROUND TERMINAL(

Strany 14 - 5.2 Outdoor Units

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 109These cases are not problems.The following incidents are not problems with the air condit

Strany 15 - 6. Piping Diagrams

Operation Manual EDUS04-904110 Room Air Conditioners H-Seriesfinfinfin

Strany 16 - 6.2 Outdoor Units

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 111groundneighboring

Strany 17 - RX15/18FVJU

Operation Manual EDUS04-904112 Room Air Conditioners H-SeriescancelsC : 3P232717-2

Strany 18 - 7. Capacity Tables

EDUS04-904 Optional AccessoriesRoom Air Conditioners H-Series 11313.Optional Accessories13.1 Option List13.1.1 Indoor UnitsNote: +1 Wiring adapter is

Strany 19 - Capacity Tables EDUS04-904

Optional Accessories EDUS04-904114 Room Air Conditioners H-Series13.2 Installation Manual13.2.1 KRP413A1S1. Functions and Features On/Off setting Sw

Strany 20 - EDUS04-904 Capacity Tables

EDUS04-904 Optional AccessoriesRoom Air Conditioners H-Series 115InstallationThis product is available in two types. The KRP413A1S · KRP413AA1S is fo

Strany 21

Optional Accessories EDUS04-904116 Room Air Conditioners H-SeriesWiring1. W iring Connect one end of the wiring to connector S21 of the PCB in theind

Strany 22

EDUS04-904 Optional AccessoriesRoom Air Conditioners H-Series 1172P031616-1BTest Operation and Confirmation1. When the System is Not WorkingIs the air

Strany 23

Optional Accessories EDUS04-904118 Room Air Conditioners H-Series13.2.2 KRP928B2SSafety PrecautionsRead these Safety Precautions carefully to ensure

Strany 24 - 8. Operation Limit

EDUS04-904 DimensionsRoom Air Conditioners H-Series 11RX24FVJUHANDLE4-HOLES FOR ANCHOR BOLTS13-3/4133/8(M8 OR M10)(I.D. φ5/8 HOSE FOR CONNECTION)1 11-

Strany 25 - 9. Sound Level

EDUS04-904 Optional AccessoriesRoom Air Conditioners H-Series 1194.Switch Settings5.Control Codes7.Combining Equipment6.Read Operating / Error Display

Strany 26 - 9.2 Octave Band Level

Optional Accessories EDUS04-904120 Room Air Conditioners H-Series13.2.3 KPW937A43P157704-2Bb)Checking the partsInstallation of LouverCAUTIONLouver 1p

Strany 27 - Sound Level EDUS04-904

EDUS04-904 Optional AccessoriesRoom Air Conditioners H-Series 12113.2.4 KPW945A4Check the following parts Installation Procedure Before installation

Strany 28 - 9.2.2 Outdoor Units

Optional Accessories EDUS04-904122 Room Air Conditioners H-Series

Strany 29

1645 Wallace Drive, Suite 110Carrollton, [email protected] 04 - 904H-Series- Heat Pump -SEER 13 ModelsEDUS 04-904 E

Strany 30 - 3D056378B

Wiring Diagrams EDUS04-90412 Room Air Conditioners H-Series5. Wiring Diagrams5.1 Indoor UnitsFTXS09/12HVJUFTXS15/18/24HVJULED1PCB2PCB3H1PINTELLIGENT-E

Strany 31 - 11.Installation Manual

EDUS04-904 Wiring DiagramsRoom Air Conditioners H-Series 135.2 Outdoor UnitsRX09/12FAVJURX15/18/24FVJUTO INDOOR UNIT60Hz 208/230V~POWER SUPPLYL2L1NOTE

Strany 32 - Safety Precautions

Piping Diagrams EDUS04-90414 Room Air Conditioners H-Series6. Piping Diagrams6.1 Indoor UnitsFTXS09/12HVJU FTXS15/18/24HVJUON HEAT EXCH.THERMISTOR(1/4

Strany 33 - Intelligent-eye Sensor

EDUS04-904 Piping DiagramsRoom Air Conditioners H-Series 156.2 Outdoor UnitsRX09FAVJURX12FAVJU3/8CuT3/8CuT9/32CuT9/32CuTTHERMISTORDISCHARGE PIPEOUTDOO

Strany 34 - Indoor Unit Installation (1)

Piping Diagrams EDUS04-90416 Room Air Conditioners H-SeriesRX15/18FVJURX24FVJUOUTDOOR UNIT1/2CuT1/2CuT5/16CuT5/16CuT5/16CuT5/16CuT5/16CuT5/16CuT5/16Cu

Strany 35 - Indoor Unit Installation (2)

EDUS04-904 Capacity TablesRoom Air Conditioners H-Series 177. Capacity Tables7.1 Heat PumpFTXS09HVJU + RX09FAVJU (60Hz 208/230V) Cooling Heating3D0575

Strany 36 - Indoor Unit Installation (3)

Capacity Tables EDUS04-90418 Room Air Conditioners H-SeriesFTXS12HVJU + RX12FAVJU (60Hz 208/230V) Cooling Heating3D057580AINDOOR OUTDOOR TEMPERATURE(°

Strany 37 - Refrigerant Piping Work

EDUS04-904Room Air Conditioners H-Series 1Split-SystemRoom Air ConditionersH-Series1. Power Supply ...

Strany 38 - Run Test and Final Check

EDUS04-904 Capacity TablesRoom Air Conditioners H-Series 19FTXS15HVJU + RX15FVJU (60Hz 208/230V) Cooling Heating3D057581AINDOOR OUTDOOR TEMPERATURE(°

Strany 39 - Choosing a Site

Capacity Tables EDUS04-90420 Room Air Conditioners H-SeriesFTXS18HVJU + RX18FVJU (60Hz 208/230V) Cooling Heating3D057582AINDOOR OUTDOOR TEMPERATURE(°

Strany 40

EDUS04-904 Capacity TablesRoom Air Conditioners H-Series 21FTXS24HVJU + RX24FVJU (60Hz 208/230V) Cooling Heating3D057583AINDOOR OUTDOOR TEMPERATURE(°F

Strany 41

Capacity Tables EDUS04-90422 Room Air Conditioners H-Series7.2 Capacity correction factor by the length of refrigerant piping (Reference)The cooling a

Strany 42

EDUS04-904 Operation LimitRoom Air Conditioners H-Series 238. Operation LimitRX09/12FAVJU, RX15/18/24FVJU114.8Outdoor temp.(°FDB)104122866832501450Ind

Strany 43

Sound Level EDUS04-90424 Room Air Conditioners H-Series9. Sound Level9.1 Measuring LocationNote: 1. Operation sound is measured in an anechoic chamber

Strany 44

EDUS04-904 Sound LevelRoom Air Conditioners H-Series 259.2 Octave Band Level9.2.1 Indoor UnitsFTXS09HVJUFTXS12HVJUFTXS15/18HVJUCOOLINGNC-40NC-30NC-50N

Strany 45

Sound Level EDUS04-90426 Room Air Conditioners H-SeriesFTXS24HVJUCOOLINGNC-40NC-30NC-50NC-60NC-20POWER SOURCEJIS STANDARD OPERATING CONDITIONSOCTAVE

Strany 46 - 11.2.1 Safety Precautions

EDUS04-904 Sound LevelRoom Air Conditioners H-Series 279.2.2 Outdoor UnitsRX09FAVJURX12FAVJURX15/18FVJUCOOLINGNC-40NC-30NC-50NC-60NC-20POWER SOURCEJIS

Strany 47

Sound Level EDUS04-90428 Room Air Conditioners H-SeriesRX24FVJUCOOLINGNC-40NC-30NC-50NC-60NC-20POWER SOURCEJIS STANDARD OPERATING CONDITIONSOCTAVE BA

Strany 48 - Installation Guidelines

EDUS04-9042 Room Air Conditioners H-Series13.Optional Accessories ...11313.1 Op

Strany 49 - Outdoor Unit Installation (1)

EDUS04-904 Electric CharacteristicsRoom Air Conditioners H-Series 2910.Electric Characteristics3D056378BRepresentative Unit Combination Power Supply C

Strany 50 - Outdoor Unit Installation (2)

Installation Manual EDUS04-90430 Room Air Conditioners H-Series11.Installation Manual11.1 Indoor Units11.1.1 Safety PrecautionsBe sure to observe this

Strany 51 - Pump Down Operation

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 3111.1.2 09/12 ClassSafety PrecautionsCAUTION• Do not install the air conditioner where g

Strany 52 - Good Wrong

Installation Manual EDUS04-90432 Room Air Conditioners H-SeriesIndoor Unit Installation DrawingsIntelligent-eye Sensor1) Do not hit or violently push

Strany 53

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 33Installation TipsIndoor Unit Installation (1)1. Removing and installing front panel.• R

Strany 54 - Construct a pedestal

Installation Manual EDUS04-90434 Room Air Conditioners H-SeriesIndoor Unit Installation (2)3.Installing indoor unit.3-1. Right-side, right-back, or ri

Strany 55 - Walls facing three sides

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 35Indoor Unit Installation (3)1) Do not use spliced wires, strand wires, extension cords,

Strany 56 - Outdoor Unit Installation

Installation Manual EDUS04-90436 Room Air Conditioners H-SeriesRefrigerant Piping Work1.Flaring the pipe end.1) Cut the pipe end with a pipe cutter.2)

Strany 57

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 37Run Test and Final Check1.Trial operation and testing.1-1 Measure the supply voltage an

Strany 58

Installation Manual EDUS04-90438 Room Air Conditioners H-Series11.1.3 15/18/24 ClassAccessoriesChoosing a Site1. Indoor unit.• The indoor unit should

Strany 59

EDUS04-904 Power SupplyRoom Air Conditioners H-Series 31. Power SupplyNote: Power Supply Intake ; Outdoor UnitIndoor Units Outdoor Units Power Supply

Strany 60

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 39Indoor Unit Installation DrawingsIntelligent-eye Sensor1) Do not hit or violently push

Strany 61 - 12.Operation Manual

Installation Manual EDUS04-90440 Room Air Conditioners H-SeriesInstallation TipsIndoor Unit Installation (1)1. Removing and installing front panel.•Re

Strany 62

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 41Indoor Unit Installation (2)3.Installing indoor unit.3-1. Right-side, right-back, or ri

Strany 63 - 12.2 09/12 Class

Installation Manual EDUS04-90442 Room Air Conditioners H-SeriesIndoor Unit Installation (3)1) Do not use spliced wires, strand wires, extension cords,

Strany 64 - Ground terminal

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 43Refrigerant Piping Work1.Flaring the pipe end.1) Cut the pipe end with a pipe cutter.2)

Strany 65

Installation Manual EDUS04-90444 Room Air Conditioners H-SeriesRun Test and Final Check1.Trial operation and testing.1-1 Measure the supply voltage an

Strany 66

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 4511.2 Outdoor Units11.2.1 Safety PrecautionsBe sure to observe this instruction.Be sure

Strany 67

Installation Manual EDUS04-90446 Room Air Conditioners H-Series11.2.2 09/12 ClassSafety PrecautionsCAUTION• Establish drain piping according to the in

Strany 68

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 47Precautions on InstallationOutdoor Unit Installation DrawingsInstallation Guidelines• W

Strany 69

Installation Manual EDUS04-90448 Room Air Conditioners H-SeriesFlare nut tightening torqueGas side Liquid side3/8 inch 1/4 inch24.1-29.4ft • Ibf 10.4

Strany 70

Functions EDUS04-9044 Room Air Conditioners H-Series2. FunctionsCategory FunctionsFTXS09/12HVJURX09/12FAVJUFTXS15/18/24HVJURX15/18/24FVJUCategory Func

Strany 71

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 49Outdoor Unit Installation (2)*1. Pipe length vs. vacuum pump run time*2. If the vacuum

Strany 72

Installation Manual EDUS04-90450 Room Air Conditioners H-SeriesOutdoor Unit Installation (3)7.Refrigerant Piping Work7-1 Cautions on Pipe Handling1)Pr

Strany 73

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 51Wiring• Do not turn ON the safety breaker until all work is completed.1)Strip the insul

Strany 74

Installation Manual EDUS04-90452 Room Air Conditioners H-SeriesRun Test and Final Check1.Trial Operation and Testing.1-1 Measure the supply voltage an

Strany 75

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 5311.2.3 15/18/24 ClassPrecautions on InstallationPrecautions for Selecting the Location1

Strany 76

Installation Manual EDUS04-90454 Room Air Conditioners H-Series• Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust air

Strany 77

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 554.Refrigerant PipingCaution1) Use the flare nut fixed to the main unit to prevent

Strany 78

Installation Manual EDUS04-90456 Room Air Conditioners H-SeriesOutdoor Unit Installation*1. Pipe length vs. vacuum pump run time*2. If the vacuum pres

Strany 79

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 57Outdoor Unit Installation7.Refrigerant Piping Work7-1 Cautions on Pipe Handling1)Protec

Strany 80

Installation Manual EDUS04-90458 Room Air Conditioners H-SeriesWiring3) Pull the wire and make sure that it is tight. Then fix the wire in place with

Strany 81

EDUS04-904 SpecificationsRoom Air Conditioners H-Series 53. Specifications60Hz 230VNote:  The data are based on the conditions shown in the table bel

Strany 82

EDUS04-904 Installation ManualRoom Air Conditioners H-Series 59Run Test and Final Check1.Trial Operation and Testing.1-1 Measure the supply voltage an

Strany 83 - Heating or Cooling

Operation Manual EDUS04-90460 Room Air Conditioners H-Series12.Operation Manual12.1 Safety precautionsAvoid exposure to airflow for long periods of ti

Strany 84

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 61Avoid direct exposure to airflow. Keep unit free of leaves and insects that can cause ma

Strany 85

Operation Manual EDUS04-90462 Room Air Conditioners H-Series12.2 09/12 Class

Strany 86

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 63Ground terminal

Strany 87 - 3P232717-1

Operation Manual EDUS04-90464 Room Air Conditioners H-Series

Strany 88 - 12.3 15/18/24 Class

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 65

Strany 89

Operation Manual EDUS04-90466 Room Air Conditioners H-Series

Strany 90

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 67

Strany 91 - INTELLIGENT EYE operation

Operation Manual EDUS04-90468 Room Air Conditioners H-Series

Strany 92

Specifications EDUS04-9046 Room Air Conditioners H-Series60Hz 230VNote:  The data are based on the conditions shown in the table below.ModelIndoor Un

Strany 93

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 69

Strany 94

Operation Manual EDUS04-90470 Room Air Conditioners H-Seriesfinsfinsbybreak. Insidefinsfins

Strany 95

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 71

Strany 96

Operation Manual EDUS04-90472 Room Air Conditioners H-Seriesoperationcenter)

Strany 97

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 73

Strany 98

Operation Manual EDUS04-90474 Room Air Conditioners H-Series

Strany 99 - COMFORT AIRFLOW

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 75

Strany 100 - EDUS04-904 Operation Manual

Operation Manual EDUS04-90476 Room Air Conditioners H-Series

Strany 101 - Operation Manual EDUS04-904

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 77

Strany 102

Operation Manual EDUS04-90478 Room Air Conditioners H-Series

Strany 103

EDUS04-904 SpecificationsRoom Air Conditioners H-Series 760Hz 230VNote:  The data are based on the conditions shown in the table below.ModelIndoor Un

Strany 104

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 79in the shade.with your hand to prevent it from falling.

Strany 105

Operation Manual EDUS04-90480 Room Air Conditioners H-Series

Strany 106

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 81,

Strany 107

Operation Manual EDUS04-90482 Room Air Conditioners H-SeriesodorHeating or Cooling. , contact the service shop where you bought the air conditioner.

Strany 108

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 83

Strany 109

Operation Manual EDUS04-90484 Room Air Conditioners H-Seriesfinfinfin

Strany 110 - These cases are not problems

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 85ground leakage breakerneighboring problems,

Strany 111

Operation Manual EDUS04-90486 Room Air Conditioners H-Series3P232717-1

Strany 112

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 8712.3 15/18/24 ClassFinsFor ,

Strany 113 - C : 3P232717-2

Operation Manual EDUS04-90488 Room Air Conditioners H-SeriesGround terminal

Strany 114 - 13.1.2 Outdoor Units

Dimensions EDUS04-9048 Room Air Conditioners H-Series4. Dimensions4.1 Indoor UnitsFTXS09/12HVJUFTXS15/18HVJUAIR FLOW (INDOOR)THE MARK (→) SHOWS PIPING

Strany 115 - 13.2.1 KRP413A1S

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 89

Strany 116 - 2. KRP413A1

Operation Manual EDUS04-90490 Room Air Conditioners H-SeriesINTELLIGENT EYE operation

Strany 117 - 1. W iring

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 91

Strany 118 - 2P031616-1B

Operation Manual EDUS04-90492 Room Air Conditioners H-Series

Strany 119 - 13.2.2 KRP928B2S

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 93

Strany 120 - 7.Combining Equipment

Operation Manual EDUS04-90494 Room Air Conditioners H-Series

Strany 121 - 3P157704-2B

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 95finsfinsfinsfins

Strany 122 - 3P089958-2C

Operation Manual EDUS04-90496 Room Air Conditioners H-Seriesfinsfinsfinsfins

Strany 123

EDUS04-904 Operation ManualRoom Air Conditioners H-Series 97

Strany 124

Operation Manual EDUS04-90498 Room Air Conditioners H-Series.operationCOMFORT AIRFLOW

Komentáře k této Příručce

Žádné komentáře